Lubri-Trak Lubricator

image006  Lubri Trak Lubricator

Download Product PDF

Maintenance
Check oil level daily and refill reservoir when required. Check the lubricator periodically for loose or broken tubing, fittings and connections.
Filter Replacement
A filter at the pump inlet protects the Lubri-Trak system. The filter disc should.be inspected every six months. If not clean, replace. To remove the filter, pry the filter housing cup loose in several places with a screwdriver. Replace new filter group, making sure coarse screen is next to pump body when installed. Replace and secure housing cup.
Service
Too little oil to carousel track: Check for broken actuator or misadjusted cam assembly, broken or cracked tubing or loose connections. Check suction filter and replace as necessary. Check applicator assembly (Data Sheet #21526). If lubricator is functioning normally, increase discharge output by turning control bypass valve clockwise. Maximum discharge is obtained at full stop position.