Multi-purpose controller for automatic lubrication systems
Easily manage your automatic lubrication system
GLC 4400 gives you programmed lubrication cycles for optimal machine performance. Customize your lubrication time, pressure, cycle counts and machine counts for maximum precision and productivity.
GLC 4400 Lubrication Controller | |
Input Contact | |
Power Source DC - model 24B591 |
9 - 30 VDC
|
Power Source AC - model 24B596 |
100 VAC to 240 VAC - 50/60 Hz
|
Power consumption |
24 Watts
|
Cycle Pressure Control Input (optional) |
Normally open pressure or cycle switch
|
Machine Count Control Input (optional) |
Machine count control switch
|
Lubrication level (optional) |
Normally open level switch, closes upon low level
|
Remote Manual Run Input |
Normally open remote manual run switch |
Outputs | |
Pump Control Voltage |
Minimum Switching Capacity |
Pump Control Max Switching Voltage |
250 VAC, 100 VDC |
Pump Control Max Switching Voltage |
10 A (AC), 5A (DC) |
Pump Control Minimum Switching Capacity |
100 mA @ 5 VDC |
Low Level Alarm Voltage |
Power Source |
Low Level Alarm Max Switching Voltage |
250 VAC, 30 VDC |
Low Level Alarm Max Switching Current |
5A (AC), 5A (DC) |
Low Level Alarm Minimum Switching Capacity |
100 mA @ 5 VDC |
Auxiliary Alarm Voltage |
Power Source |
Auxiliary Alarm Max Switching Voltage |
250 VAC, 30 VDC |
Auxiliary Alarm Max Switching Current |
5A (AC), 5A (DC) |
Auxiliary Alarm Minimum Switching Capacity |
100 mA @5 VDC |
Status OK Voltage |
Power Source |
Status OK Max Switching Voltage |
250 VAC, 100 VDC |
Status OK Max Switching Current |
10 A (AC), 5A (DC) |
Status OK Minimum Switching Capacity |
100 mA @ 5 VDC |
Protection grade |
IP69K |
Enclosure Material |
Fiberglass reinforced polyester |
Membrane Material |
Polyester |
Bushing |
Ethylene Propylene Diene Monemer Rubber (EDPM) |
Operating temperature range |
- 40°F to 145°F |
Storage Temperature |
- 13°F to 145°F |